(512) 540-3010
info@bassg.com
Software Solutions for Energy Efficient, Intelligent Buildings
EnerCase Integration With Niagara Framework
Sparko - SkySpark CMMS Integration Driver with Kayako
Energy DVR-Energy Dashboard with playback integrated with SkySpark
Project Builder Plus-Project Haystack Integrated Desktop Enviroment (IDE)
Sedona Framework-Ontrol & Solidyne Devices
SkySpark Energy Analytics Framework
Air Hippo Energy Data Push Framework by BASSG
basMaker BMS Visualization Platform
Niagara PX Generation
Made Easy
Watch the video to see the benefits of basTemplateMavi
EnergyDVR with basMaker
Great for:
Playback your graphics in Niagara built with Px.
Educational Dashboard Playback of any graphic.LEED dashboards Integrates with SkySpark leading Energy Analytics Software
find what matters
Collect, Organize, Analyze, Visualize, Report
Niagara Framework with basmaker bundle
Niagara 4
EDGE ANALYTICS CONTROLS IS THE NEW FRONTIER ON CONTROLLING, ANALYZING AND OPTIMIZING SMART BUILDING SYSTEMS.
Future of building IOT
Following companies used our products & services
previous arrow
next arrow
Slider

Join into the intelligent build revolution

Start the process for smart, efficient and interconnected buildings.

Intelligent Buildings

From hardware to software, we control every part of the project.

Work-flow software with sound technology

We have more than 10 years of in software development in workflow enhancement software.

Visualization & Dashboards

12 years of experience in 3D visualization & UX design.

Data Analytics

4 years experience in Big data solutions including custom programming.

BASSG difference

Win for the facility! Win for the contractor! & Win for the environment!

Sparko

SkySpark analytics can find tremendous amounts of operational issues just looking at systems data. Once found those issues need to be resolved. Sparko lets you easily manage the workflow of resolving your Sparks.

SkySpark

SkyFoundry’s SkySpark analytics software automatically analyzes building, energy and equipment data to identify issues, faults and opportunities for energy and operational savings. SkySpark helps building owners “find what matters” in the vast amount of data produced by today’s smart systems and is an ideal fit for operators of large portfolios.

Air Hippo

Data push framework with Alerton Access, SQL, BACnet/IP, Haystack pipelines

Project Builder Plus

Streamline the engineering effort of setting up SkySpark projects with Project Builder Plus, a fantom based desktop application with templates, syncronization, haystack library, time-series data push & so much more.

Intelligent Buildings

Edge Analytics Controller

Real-time Controls + Analytics Engine + Visualization HYBRID CONTROLLER

Visualytik

Visualytik stands for visual + analytics. ​Drag and drop GUI items Block programming Page manager It is built-on SkySpark framework and utilizes project haystack in its core.

basMaker

basMaker is Niagara Framework work-flow enhancement tools. AHU, Plant, Unitary, Aron, Data Center, Temp Specs, RTU makers are in the library.

EnergyDVR

EnergyDVR dashboard renders px pages in Flash which plays back runtime of equipment from a selected date. All within Niagara Framework.

EnerCase

Based on Niagara Framework head-end controls and supervisor. EnerCase devices are bundled with basMaker products.

Company Accomplishments

In 12 years, BASSG has saved a tremendous amount of hours to contractors and successfully completed projects.

Hours Saved

Happy Clients

Awards Nominated

Completed Projects

Testimonials

I would definitely recommend this to anyone needing an easy to use graphics library. The module looks great. I have been looking for a graphics library that is Widget based and this is it. Very easy to use and everything lines up easily. I especially like the damper module since it can be reversed and re-scaled to fit different manufacturers signal limitations without having to do additional work. I would definitely recommend this to anyone needing an easy to use graphics library.
Allen Willis
Controls Department - Performance Services
BASSG has provided high-quality graphics for many of our customer projects. We value his industry knowledge, quick turnaround, and attention to detail. We will definitely be coming back for more!
Francis Chapman
Marketing Director, ASI Controls - ASI Controls
The template design has gone above and beyond our expectations which are superior to anything on the market today! The modules are wonderfully balanced and are almost too easy to use. The template design has gone above and beyond our expectations which are superior to anything on the market today. These are the reasons we will stay a step ahead of our competition and allows us to provide quality of graphics that match our service.
Clifford Millian
Systems Integrator - Controlco
I have worked with BASSG on 3 recent jobs; BASSG is very committed to providing high end graphics while also keeping the project on schedule and paying great attention to detail. We would definitely recommend them and look forward to working with them on our next project.
Paul Kennedy Jr
I am extremely satisfied with the graphical services we have received from BASSG. They allow us to focus on what we do best in controls, we in turn provide our customers what they do best and this provides a very satisfying experience to our end users. Reasonable pricing, excellent persistence and workmanship.
Eric S.
Systems Integrator - Siemens
I'm very pleased with the service received from BASSG. Great turn around time with high quality graphics for professional front ends. Keep up the good work!
Chris W.
J&H Heating Inc.
This is taking our end product to a whole other level!
S. Hilaire
Control Technologies, Inc.

Latest from our Blog

Modbus Controllers

M/TIO modules are general purpose input/output modules with industry-standard, open-protocol modbus RTU communications.

Both modules have the same I/O configuration, the only difference is the communications protocol.

These modules also host a battery backed-up real-time-clock.Therefore, time schedules can be implemented directly on the device, fully configurable locally from the connected R-ION or remotely from a supervisory system.

Chinese students so we could be better centered around the lecture.... The teacher typically avoids our column to just converse with the remainder of the class.. .has an inclination that we were not there. I realize that we don't volunteer a lot to address his inquiries.. .not excessively we would prefer not to take an interest, it just sets aside us longer effort to sort out our contemplations in English. We felt being treated as though we were not as savvy as American friends who can type essay for you and help with any assignment. With a comparable encounter, Enyang revealed that an American male student in her investigation bunch never reacted to her inquiries in email and even left her when she was disclosing her plans to him. I disclosed to him and different students in my investigation bunch my opinion of the task. His reaction was essentially "I don't see." So I was clarifying again however he just left the talk. Absence of Support for ESL Learners. Another test of being an ESL student is absence of help for and comprehension of ESL students in doctoral projects. The respondents detailed that in spite of the fact that there were assets and backing for ESL students, a significant number of them were at the school level and obliged college students. Gangdu communicated an inclination to improve his English in academic writing, however tragically the college writing focus was accessible for college students.
  • M/TIO Input/output module (Modbus RTU comms - RS485)
  • 8 Analog in
  • 2 triac out (on/off, PWM or floating)
  • 4 analog out (0-10Vdc)
  • 3-speed fan relays (can be used individually)
  • 1 high-power relay (10A)
  • 1 additional relay (5A)
  • 24 Vac supply

Universal Inputs :

8 inputs are provided, which can be configured as follows:

Input Pt1000 NTC 0-10 V Contact
In1 - Yes - Yes
In2 - Yes - Yes
In3 - Yes - Yes
In4 - Yes - Yes
In5 Yes - - Yes
In6 Yes - Yes Yes
In7 Yes - Yes Yes
In8 Yes - Yes Yes

Relay Outputs : Five relay outputs are provided, each with 5A rating.

Triac Outputs : 2 triac outputs are provided with flexble configuration options, allowing control of on/off thermoeelectic (PWM) or floating actuators or relays. The triacs can be independently configured to control different loads. However, due to internal connections, all loads must be supplied from the same AC voltage. Floating (three-position) configuration requires use of both triacs.

Modulating Outputs : Four 0-10VDC analog outputs are provided for controlling modulating valve or damper actuators. Two of these points can be configured to function as digital inputs.

Expansion port : Upto two RK4 relay modules can be connected to the device with a ribbon cable, providing up to a total of 8 additional relay outputs.

Real-Time-Clock : 4 time-schedules can each be independently associated with a relay output through configuration parameters. Each schedule allows 28 sets of start/stop times per week.

VERSIONS Supply Comms
M/TIO-U 120 Vac Modbus RTU Slave
M/TIO-H 230 Vac Modbus RTU Slave
M/TIO-L 24 Vac Modbus RTU Slave